Scale, corrosion, fouling and biology — the four things that quietly steal heat-transfer efficiency and shorten the life of every cooling system. We control all four.
A cooling tower concentrates whatever is in its make-up water. As water evaporates, hardness, silica, chloride and sulphate climb with every cycle of concentration; warm, aerated, nutrient-rich water is also the ideal home for algae, bacteria and Legionella. Left alone, the result is scale on condenser tubes (a 1 mm calcium carbonate layer can cut heat transfer by 10 % or more), corrosion of carbon steel and copper alloys, biofilm that insulates and corrodes, and fouling that blocks fill and nozzles.
Cooling water treatment is the combination of make-up water quality, mechanical filtration, chemical dosing and blowdown control that keeps the system clean at the lowest total cost of water, chemicals and energy. We design it as a system, not as a chemical programme sold by the drum.
Automatic backwash multimedia or screen filters, 5–500 m³/h, with controls.
Multi-pump skids with day tanks, flow-proportional and ORP/pH-controlled dosing.
Reduce make-up hardness and TDS to run 6–10 cycles safely.
Recover blowdown as make-up; reject managed with ETP or ZLD.
Conductivity controller, motorised valve, flow totaliser.
Risk assessment, sampling plan, biocide regime, documentation.
Inhibitors, biocides, dispersants — see our treatment chemicals page.
Monthly service visits, testing, dosing optimisation, reporting.
Water audit — make-up analysis, system volume, heat load, current cycles and chemical spend → treatment design and water balance → supply of filtration, dosing and RO skids → commissioning and programme setup → monthly O&M with reports. We also take over and optimise cooling systems already under another vendor's programme.
Typically 4–8 with raw make-up water and up to 10–15 with softened or RO make-up. The limit is set by the scaling index of the concentrated water — we calculate it from your make-up analysis.
A filter that continuously treats 3–10 % of the recirculating flow, removing suspended solids that scrub into the tower from air and corrosion. Almost every open cooling system benefits; dusty or biologically active sites cannot run cleanly without it.
A written risk assessment, controlled oxidising biocide with ORP monitoring, periodic non-oxidising shots, cleanliness of the basin and fill, and regular sampling. Documentation is part of the programme.
Yes — after softening or RO, 60–80 % of blowdown can return as make-up. The reject goes to the ETP or evaporator.
Send the make-up analysis, system volume and current chemical programme — we reply with a treatment plan and water-saving estimate within one working day.